E4S3200
The ABB E4S3200 is a high-capacity low-voltage air circuit breaker from ABB’s Emax E4S series, designed for industrial and commercial three-phase power distribution systems. It provides reliable protection against overloads, short-circuits, and fault conditions when used with an appropriate electronic trip unit. The breaker can be used as a main distribution breaker or feeder protection device in switchgear installations. It is available in various configurations, including fixed or withdrawable mounting, and supports electronic trip units such as PR121/P-LI or PR121/P-LSIG for adjustable and coordinated protection.
FISHER 657
Technical Parameters
Category Parameter Specification / Description
General Model Series 657
Type Pilot-Operated Pressure Reducing Regulator
Pressure & Temperature Body Rating (ANSI) ANSI Class 150, 300, 400, 600, 900
Max. Inlet Pressure (P1) Up to 1440 psig (99 bar) for certain classes.
Outlet Pressure Range (P2) Wide range, adjustable via the pilot spring. Common ranges from 5 to 500 psig (0.3 to 34 bar) or higher.
Flow & Sizing Flow Capacity (Cv) Very High. Ranges from ~30 to over 1000+, depending on the valve size (e.g., 1", 2", 3", 4", 6", 8").
End Connections Flanged (RF, RTJ) according to ANSI standards.
Materials & Construction Body Materials Carbon Steel (Standard), Stainless Steel, Other Alloys.
Trim Materials Stainless Steel.
Pilot Valve 657 Pilot (Reducing Pilot) - senses downstream pressure.
Options Common Pilot Options • Monitor Pilot: For overpressure protection.
• SLM (Slow Opening) Pilot: For safe start-up.