Key Parameters
Category Description / Value
Product Line Eaton BZM Explosion-Proof Enclosures
Type Explosion-Proof Junction Box
Body Material Cast Aluminum
Hazardous Location Class I Division 1, Class II Division 1, Class III
Enclosure Rating NEMA 4X
Protection Level IP66/IP67
Conduit Entries Multiple threaded openings
Cover Bolted cover with sealing surface
Key Parameters
Category Description / Value
Product Line Eaton BZM (Explosion-Proof Enclosures)
Type Explosion-Proof Junction Box
Rated Current 32 A (for internal components/terminals)
Body Material Typically Cast Aluminum or other non-corrosive, non-sparking material.
Hazardous Location Classifications Certified for Class I, Division 1, Class II, Division 1, and Class III groups (Exact certification must be verified from product documentation).
Enclosure Rating Typically NEMA 4X (Weatherproof and Corrosion-Resistant)
Conduit Entries Multiple threaded openings (specific number and size defined by the "X1N-3" code).
Cover Bolted cover with an integral sealing surface to maintain explosion-proof integrity.
Internal Volume Specific internal cubic capacity for housing connections.
Key Parameters
Category Description / Value
Product Line Eaton 9SX UPS Series
Type Online Double-Conversion UPS
Rated Power Capacity 3000 VA / 3000 W
Input • Voltage: 120 V AC
• Connection: IEC connector (e.g., NEMA 5-15P)
• Phase: 1-Phase
Output • Voltage: 120 V AC
• Connection: IEC outlets (e.g., (5) IEC 320 C13 outlets)
• Phase: 1-Phase
Topology Double-Conversion Online
Typical Runtime Varies based on load; extended runtime available with external battery packs (EBM).
Display/Interface LCD status display and control buttons.
Communication USB, Serial, and optional network management card slot.
Form Factor Tower
Key Parameters
Category Description / Value
Product Line Eaton FAZT (Fuse Switch Disconnectors)
Rated Operational Current (Iₑ) 320 A (for the switch mechanism)
Utilization Category AC-22B (for switching mixed resistive and inductive loads) or AC-23B (for switching motor loads) - Must be verified from datasheet.
Rated Operational Voltage (Uₑ) Up to 690 V AC
Rated Insulation Voltage (Uᵢ) 690 V / 1000 V
Switch Function Load switching and isolation
Protection Provided by external DIN-type fuses (e.g., 00 or 1 size, up to 320A)
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Connection Screw terminals.
Standards Compliance IEC/EN 60947-3
Key Parameters
Category Description / Value
Product Line Eaton NZM3 Accessories
Compatible Breakers NZM3 Motor Protection Circuit Breakers (e.g., NZM3-XV... series)
Function Analog Setting Digitization Module / Motor Drive Interface
Input Reads the physical position of the breaker's analog setting potentiometers.
Output Digital data representing the breaker's current settings.
Communication Interface Typically requires connection to a System Interface (SI) module (e.g., XV-SI) for integration into a network (e.g., Profibus, DeviceNet, Modbus-TCP).
Mounting Designed to be mounted directly onto the compatible NZM3 breaker.
Purpose • Setting Read-back: Allows a control system to read the actual protection settings configured on the breaker.
• Condition Monitoring: Verifies that the settings have not been manually changed without the control system's knowledge.
• Documentation: Provides digital documentation of protection parameters.
Key Parameters
Category Description / Value
Product Line Eaton DILM (Contactor) & Accessories (Timer)
Compatible Contactor DILM115C
Contactor Rated Operational Current (Iₑ) at AC-3 115 A (For squirrel-cage motors)
Contactor Rated Operational Power at AC-3 ~ 55 kW / 75 HP at 400V 50Hz
Contactor Poles 3 (Main Contacts)
Contactor Coil Control Voltage DC - The specific voltage (e.g., 24V, 110V DC) must be confirmed by the order code sticker on the contactor itself.
Module Type Timer Module
Timer Function Specific function (e.g., On-delay, Off-delay, Star-Delta) as defined by "GC" code.
Module Power Supply Derived from the main contactor coil circuit.
Mounting Snap-on mounting directly onto the DILM115C contactor.
Standards Compliance IEC/EN 60947-4-1
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 16 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 25 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 32 A
Number of Poles 1-Pole
Tripping Characteristic C-Curve (Instantaneous trip between 5-10 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (e.g., 6 kA, 10 kA).
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail).
Connection Screw terminals.
Key Parameters
Category Description / Value
Product Line Eaton PL (Miniature Circuit Breakers)
Rated Current (Iₙ) 63 A
Number of Poles Typically available in 1-Pole, 2-Pole, 3-Pole, and 4-Pole versions
Tripping Characteristic D-Curve (Instantaneous trip between 10-20 x Iₙ)
Rated Operational Voltage (Uₑ) 230/400 V AC
Rated Insulation Voltage (Uᵢ) 500 V
Breaking Capacity According to IEC/EN 60898 standard (typically 10 kA)
Standards Compliance IEC/EN 60898-1
Mounting Snap-on mounting on 35 mm top-hat rail (DIN rail)
Connection Screw terminals