The ABB A12‑30‑10 is a three‑pole electromechanical AC contactor from ABB’s A‑line series, designed for switching and controlling three‑phase motors and general power circuits. It features a compact design with screw terminals and is suitable for use with thermal overload relays and auxiliary contact blocks to form complete motor starter assemblies. This model is configured with a 110 V AC (50 Hz) / 110–120 V AC (60 Hz) coil for industrial control and automation applications
The ABB 1SDA092547R1 is a four‑pole (4P) molded case circuit breaker (MCCB) from ABB’s low‑voltage protection range. It combines adjustable thermal‑magnetic trip protection with fixed and cable‑ready terminal options, providing reliable overload and short‑circuit protection for three‑phase electrical distribution networks. This breaker is suitable for industrial and commercial electrical systems where coordinated circuit protection and robust performance are required. The product may also be supplied with additional modules (such as a residual current or auxiliary interface) depending on variant.
IEC/EN 60947‑4‑1 is an international standard for low-voltage switchgear and controlgear—specifically contactors, motor starters, and overload relays for AC and DC motors. ABB equipment designed according to this standard ensures safety, reliability, and interoperability in motor control and protection applications. The standard defines performance, electrical, mechanical, and environmental requirements for devices controlling motors, including manual and automatic starters, contactors, thermal overload relays, and associated control units.
The ABB MS132‑20 (1SAM350000R1013) is a compact manual motor starter / motor protection breaker designed to manually start and stop small motors and provide built‑in protection against overload, short‑circuit, and phase failure without requiring separate fuses. It is suitable for three‑phase and single‑phase motors and is commonly used in control panels, machinery, and industrial and commercial motor protection applications. The device features a thermo‑magnetic tripping mechanism, a rotary handle with clear ON/OFF/TRIP indication, and a lockable handle for safety.
The ABB 1SDA067013R1 is a three‑pole molded case circuit breaker (MCCB) from the ABB SACE Tmax XT2N series. It features a thermal‑magnetic (TMD) trip unit with an adjustable setting range for overload and short‑circuit protection from 32 A up to 320 A. The breaker has front fixed terminals (FF) for straightforward installation and termination in electrical distribution panels, motor control centers, and industrial switchgear. It offers dependable circuit protection for low‑voltage power distribution applications
The ABB CT‑MBS.22S (1SVR730010R3200) is a multifunction electronic time relay from ABB’s CT‑S timer series. It provides a wide variety of configurable timing functions and flexible time ranges to control and delay electrical circuit operations in automation and control systems. This relay supports both AC and DC supply voltages and features dual change‑over (SPDT) output contacts for versatile switching. It is designed for DIN‑rail mounting in control panels and industrial automation applications.
The ABB 2CSF204005R1800 is a four‑pole residual current circuit breaker (RCCB) from ABB’s F200 series, designed to detect and interrupt earth leakage (ground fault) currents to protect people and electrical installations. It continuously monitors the difference between phase and neutral currents and trips the circuit if residual (leakage) current exceeds a set threshold, helping prevent electric shock and fire hazards. This product conforms to international IEC safety standards and is suitable for low‑voltage AC power systems such as residential, commercial, and light industrial distribution boards.
The ABB MS495‑63 (1SAM550000R1007) is a manual motor starter with built‑in thermomagnetic protection designed to manually switch motors on and off and to provide reliable protection against overload, short‑circuit and phase failure conditions without requiring external fuses. It features a rotary handle with clear ON/OFF/TRIP position indication and is suitable for use with three‑phase and single‑phase motors in industrial and commercial installations. The starter includes a built‑in disconnect function and temperature compensation for enhanced motor protection.
The ABB XT2N 160 TMG 16‑160 3P FF is a three‑pole molded case circuit breaker from ABB’s SACE Tmax XT2N series. It features a TMG thermal‑magnetic trip unit with adjustable trip range from 16 A up to 160 A for reliable overload and short‑circuit protection. The breaker is equipped with front fixed terminals (FF) that simplify installation in distribution panels, switchboards, and motor control centers. This robust breaker provides dependable circuit protection for industrial and commercial electrical systems
The ABB 1SDA050922R1 is a three‑pole molded case circuit breaker from ABB’s SACE Tmax T1N series, designed for protection and manual switching in low‑voltage electrical distribution systems. It features a TMD thermo‑magnetic trip unit with adjustable overload and short‑circuit protection range from 100 A to 1000 A, and front fixed & front cable (FFC) terminals for easy installation with copper cables. The breaker provides reliable protection against overloads and short‑circuits in industrial, commercial, and distribution panel applications.