Specifications
Parameter Category Details
Manufacturer & Series Schneider Electric, PowerLogic EM Series 5800
Complete Model Number BMEP586040
Device Type Three-Phase Power & Energy Meter (Network Analyzer)
Measurement Input 3-Phase + Neutral (Direct measurement or via Current Transformers - CTs)
Voltage Rating Up to 480V AC line-to-line (Phase-to-phase)
Current Input • Direct Input: Up to 10A (for small circuits).
• Via CTs: Standard 5A or 1A secondary; supports a wide range of primary CT ratios.
Measurement Capabilities Electrical Parameters:
• Voltages (L-N, L-L), Currents, Neutral Current
• Active, Reactive, Apparent Power (per phase and total)
• Power Factor, Frequency
• Energy: Import/Export (kWh, kVARh)
• Demand: Current and Power (kW, kVA, kVAR) with sliding window
• Power Quality: Harmonics (THD, up to 31st or 63rd harmonic), Unbalance, Voltage Sags/Swells, Alarms
Accuracy Class • Active Energy (kWh): Class 0.5S or Class 0.2S (IEC 62053-22)
• Voltage & Current: Typically ±0.2% of reading
• Power: Typically ±0.5% of reading
Display Large, backlit Graphical LCD Display (or high-resolution segment display, depending on version) for showing readings, trends, and alarms.
Communication Ports Typically includes:
• 2x Ethernet Ports: For Modbus TCP/IP, BACnet IP, or embedded web pages.
• 1x RS-485 Serial Port: For Modbus RTU or BACnet MS/TP.
Power Supply 85-265V AC/DC or 24V AC/DC (depends on specific order code variant; typically wide-range AC/DC).
Real-Time Clock (RTC) Integrated, battery-backed for time-stamping events and demand calculations.
Memory & Logging Internal memory for storing historical data, such as:
• Load Profile (consumption over time)
• Min/Max/Average values
• Power Quality Event Logs (sags, swells)
• Alarm History
Alarms/Relay Outputs Configurable digital outputs (relays or solid-state) for signaling alarms (e.g., overload, under-voltage, demand threshold). Number of outputs varies (often 2 or 4).
Digital Inputs Typically 2-4 digital inputs for status monitoring (e.g., external breaker status, pulse counting from other meters).
Operating Temperature -10°C to +55°C (or -25°C to +70°C for extended range models)
Protection Rating IP40 (front panel) for panel mounting.
Mounting Panel-mounted via a cutout (standard 92mm x 92mm or 144mm x 144mm cutout).
Standards & Certifications IEC 61557-12, ANSI C12.20, UL, CE, RoHS.
Configuration Software PowerLogic ION Setup or EcoStruxure Power Monitoring Expert for advanced configuration and data management.
Typical Applications Main incomer and sub-feeder monitoring in commercial buildings, industrial energy management, utility metering, data center power monitoring, power quality analysis, and tenant billing.