TM5SBET1

The Schneider Electric TM5SBET1 is a single-port Ethernet/IP adapter module from the Modicon TM5 distributed I/O system (specifically, the "Performance" or "SB" line). It serves as the communication interface (bus coupler) between a Modicon TM5 I/O island and an EtherNet/IP network.

open
TEL:+86 13600179521
Mail:info@hongkongeasy.com
info@hongkongeasy.com
WhatsApp
Parameters
Request a Quote
Return to List
Specifications Parameter Category Details Manufacturer & Series Schneider Electric, Modicon TM5 System (Performance Line - SB) Complete Model Number TM5SBET1 Module Type EtherNet/IP Adapter (Bus Coupler) Module Fieldbus Protocol EtherNet/IP Adapter Conformance Tested Yes, by ODVA. Network Ports 1x Ethernet Port (RJ45), 10/100 Mbps, Auto-MDIX. Supported Services • I/O Data Exchange (Implicit Messaging): Cyclic I/O data transfer (Input/Output assemblies). • Explicit Messaging: For configuration, diagnostics, and non-time-critical data (CIP services). Number of Supported Connections Supports multiple CIP connections (both Input and Output). The exact number is defined by the configured I/O assembly size and scanner capabilities. I/O Update Time Depends on network configuration, scanner settings, and the amount of I/O data. Typically sub-10ms range for moderate-sized islands. TM5 Backplane Power Supplies 5V and 24V DC to the connected TM5 I/O modules via the TM5 bus. TM5 Bus Expansion Allows connection of up to 12 additional TM5 modules on the same island (via the TM5 bus). The total number is limited by the 5V backplane current budget. Configuration Configured using: 1. EcoStruxure Machine Expert (for initial module and I/O mapping setup). 2. An EDS (Electronic Data Sheet) file is used in the EtherNet/IP scanner's configuration software (e.g., Rockwell Studio 5000) to easily import the device profile and I/O assembly. Status Indicators • Module Status LEDs: Power, Network Status, Network Activity, Module Run/Error. • TM5 Bus Status LED. IP Address Assignment Via BOOTP/DHCP or Static IP (configured using the module's rotary switches or software tools). Power Supply Requires an external 24V DC power supply connected to its terminals to power the module and the entire TM5 I/O island. Power Consumption (from 24V) Depends on the connected I/O modules. The adapter itself typically consumes ~200-300 mA. Operating Temperature 0°C to +60°C Storage Temperature -25°C to +70°C Protection Rating IP20 (for installation inside an enclosure). Mounting Mounts on a standard DIN rail (35mm). The first module in a TM5 island must be a bus coupler (like this one). Typical Applications Integrating Schneider Electric TM5 I/O into Allen-Bradley control systems, or any system using an EtherNet/IP scanner. Common in machine automation where multi-vendor interoperability is required.